ESR Series Stabilisers and Power Line Conditioners are available capable of supporting a number of Nominal Three Phase Voltage environments.

  • H Series – International – 380/400/415V – 50/60Hz
  • H-X468 Series – US Style – 440/460/480V – 50/60Hz

Models are available as either 4 Wire with Neutral or 3 Wire without Neutral solutions.

 

For further details please check-out the Series TABs below –

+ Permissible Input Voltage Window Options & Output Voltage Accuracy >

SWING-ESR-250-3750-sm2

Input Voltage Windows:

In situations where there is a reasonably good mains supply, a Stabiliser offering an input variation swing of ±15% (S15 Models) will usually be more than acceptable, but in more remote locations, or countries where the national supply infrastructure is less developed, variations of ±20% (S20) or greater ±25% (S25) to ±50% (S50) may be needed to be accommodated by the Stabiliser.

TIP – The wider the permissible input voltage window you wish the Stabiliser to be able to accommodate , the more expensive the Stabiliser. So, when selecting the most appropriate and cost efficient model for your application, it pays to know the state of the utility mains supply on site and the designed input voltage tolerances of the load equipment you wish to protect.

Output Voltage Accuracy:

In general, when suppliers of today’s modern electrical and electronic equipment design their products they do so knowing that most electrical utilities around the world cannot provide, or promise, better than a ±5% output voltage accuracy of nominal and as such they design their equipment so it is able to operate efficiently within this range.

ESR Stabilisers are specifically designed to meet the requirements of today’s modern loads, with the output voltage accuracy set (as default) to deliver optimal energy efficiency and design life expectancy at ±3% , however they are easily site-adjustable to deliver a more or less precise output voltage accuracy – as considered most appropriate for a client’s particular site needs.

+ General Technical Specifications >

This Specification covers the general technical performance of the H Series (380 to 415V) Three Phase 4 Wire (with Neutral) ESR Series Voltage Stabilisers / Power Line Conditioners in ratings from 250 to 3750 kVA.

NB:  3 Wire (without Neutral) HD Series models are also available – please checkout the Brochure Downloads TAB on the right to download the relevant HD Series brochure.


SPECIFICATION
GENERAL
Design Topology: Static -Digital Buck-Boost SCR Design
Electrical Configuration: Three Phase, 4 Wire, (3 Phase + Neutral + G/E)
Power Ratings: 250 kVA, 300 kVA, 350 kVA, 400 kVA, 450 kVA,
500 kVA, 600 kVA, 650 kVA, 700 kVA, 750 kVA,
800 kVA, 900 kVA, 1000 kVA, 1200 kVA, 1250 kVA,
1500 kVA, 1600 kVA, 2000 kVA, 2500 kVA, 3000 kVA
3125 kVA & 3750 kVA
- smaller ratings to order
Power Factor: The Power Factor has no effect on performance providing
the stabiliser is being used within its rated capacity
Frequency: 35 to 63Hz
INPUT
Voltage: 380/220V - 400/230V - 415/240V (Customer to Specify)
Voltage Swing Options
Available:
±15% (S15 Models - up to 3750 kVA)
±20% (S20 Models - up to 3750 kVA)
±25% (S25 Models - up to 2500 kVA)
±30% (S30 Models - up to 2000 kVA)
±35% (S35 Models - up to 1200 kVA)
±40% (S40 Models - up to 1200 kVA)
±45% (S45 Models - up to 1200 kVA)
±50% (S50 Models - up to 1000 kVA)
(Customer to Specify)
Frequency: 35 to 63Hz
OUTPUT
Voltage: 380/220V - 400/230V - 415/240V
(Customer to Specify)
Voltage Regulation: S15 to S20 Models ±3% (Default) - Adjustable ±1 to ±5%
S25 to S40 Models ±3% (Default) - Adjustable ±3 to ±5%
S45 to S50 Models ±5%
Frequency: 35 to 63Hz
Response Time: <0.04 seconds
Correction Time: 40 msec per Step
PROTECTION FEATURES
Surge Suppression: TVSS - Protects loads against high energy
Spikes and Transient Voltages
SPD Surge Arrestors: Class 2 Type Surge Protection Device - protects the load
and stabiliser against high energy voltage spikes of
operational or atmospheric origin (eg. Lightning induced spikes)
Independent Phase
Control:
Maintains each phases voltage stable irrespective of load
unbalance, even up to 100% load unbalance
Start-Up Protection: Protection of the load equipment from damaging start up
voltage surges
Automatic Bypass: Automatic transfer to bypass in the event of an
overload or system problem
Overload Capacity: 5 x max. current rating for 1 second
1.5 x max. current rating for 1 minute
Short Circuit & Overload
Switch / Breaker Protection
and Manual Bypass
facility:
250 to 400 kVA Rated Models
Type 1 (T1) style switch arrangement
consists of an input switch and bypass switch, with output
isolation, with mechanical interlocking to prevent
inadvertent mis-operation

450 to 2000 kVA Rated Models
Type 2 (T2) style switch arrangement consists of a
motorised input air switch and output / bypass changeover
switch, with full electronic interlocking to prevent inadvertent
mis-operation

2500 kVA + Rated Models
Type 3 (T3) style switch arrangement similar to the
Type 2 arrangement, but utilising separate motorised
air output and bypass switches, with full electronic interlocking
to prevent inadvertent mis-operation

For further details see Breaker / Switch Configurations and
Control Panels Tab below

ENVIRONMENTAL
Operating Temperature
Range:
Temperature range 0 to 45 °C
Derate by 2% for each additional °C Up to max 60 °C
Maximum Altitude: Maximum altitude 4000m
Derate by 2.5% for each additional 500m
Relative Humidity: Suitable for indoor tropical use 90% RH (non-condensing)
Efficiency: =>98%
THD - Harmonic Distortion: None introduced
Audible Noise: < 45 dB (at 1 Metre)
PHYSICAL
Construction: Enclosures to IP20 (NEMA 1 Style) - BS EN 60529
Colour: RAL 7032 (Pebble Grey - Epoxy Powder Coating)
Dimensions & Weights: See S15 to S50 Tabs below
CONFORMANCE
EMC Conformance: Complies with BS EN 55022 and the relevant parts of
the BS EN 61000 series of standards
CE Certification:: CE Marked - being fully compliant with European Union
Directives 2014/30/EU (The EMC Directive) and
2014/35/EU (The Low Voltage Directive)
WARRANTY
Standard Warranty: 2 Year / 24 Months from date of supply
Extended Warranty: Option - Extendable Warranty up to 60 Months / 5 Years
ADD-ON OPTIONS
Input Isolating
Transformer:

(-PC)
Through the inclusion of a shielded isolation transformer,
provides enhanced spike & electrical noise (common &
normal interference) suppression and neutral
ground bonding. Delivers what is commonly
referred to as a ‘CLEAN’ supply
Outdoor IP54
Ingress Protection:

(-IP54)
Stabiliser presented in an endurable IP54 (BS / EN 60529)
/ NEMA 3 free standing steel cubicles suitable for
external use, or more challenging internal environments
AquaStop:
(-AS)
PCB protective coating offering protection against
damp and moisture ingress
Alternative Switch
Arrangements:

(-T2 or T3)
Alternative Input, Output and Bypass Switching arrangements
- T2 (250 to 400 kVA)
- T3 (250 to 2000 kVA)
See Short Circuit & Overload Switch / Breaker Protection
and Manual Bypass facility Section above
Additional Metering:
(-ADM)
Additional Digital Metering for
- Input Volts
- Frequency
- Power Factor
4 Pole Switches / Breakers:
(-FP)
As standard ESR Stabilisers utilise 3 Pole Switches / Breakers.
As an option 4 Pole alternatives can be supplied.
eSpec Upgrade:
(-eSP)
While we endeavour to keep production costs to a minimum
by sourcing top specification components from
around the globe we realise that some clients have a
requirement for their own designated protection devices

Accordingly we are able to offer our eSpec Pack Upgrade
package which offers the client the short circuit and
overcurrent protection components from their preferred
leading European or American manufacturers

+ S15 Models - Input Voltage 380/400/415V ±15% >

Input & Output Voltages:
Permissible input voltage windows & output voltage accuracies available for H Series S15 models.


S15 Models / Nominal 380/220V 400/230V 415/240V
Input Voltage Swing % 380V ±15% 400V ±15% 415V ±15%
> L-L Voltage Window 323 to 437V 340 to 480V 353 to 477V
> L-N Voltage Window 187 to 253V 196 to 265V 204 to 276V
Output Voltage Accuracy
> Adjustable
380V ±3% (Default)
±1% to ±5%
400V ±3% (Default)
±1% to ±5%
415V ±3% (Default)
±1% to ±5%
Ratings 250 to 3750 kVA 250 to 3750 kVA 250 to 3750 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings with physical sizes and weights –


ESR Model No Rating
kVA
Amps
per Phase
Case
Style
Physical Size
W x H x D (mm)
Weight
Kg
ESR-250H-3P-T1-S15 250 kVA 380 @ 380V
361 @ 400V
348 @ 415V

C14

1050 x 2000 x 700 550 Kg
ESR-300H-3P-T1-S15 300 kVA 456 @ 380V
433 @ 400V
417 @ 415V

C14

1050 x 2000 x 700 680 Kg
ESR-350H-3P-T1-S15 350 kVA 532 @ 380V
505 @ 400V
487 @ 415V

C14

1050 x 2000 x 700 780 Kg
ESR-400H-3P-T1-S15 400 kVA 608 @ 380V
577 @ 400V
556 @ 415V

C14

1050 x 2000 x 700 800 Kg
ESR-450H-3P-T2-S15 450 kVA 684 @ 380V
649 @ 400V
626 @ 415V

C15

1200 x 1600 x 800 890 Kg
ESR-500H-3P-T2-S15 500 kVA 759 @ 380V
721 @ 400V
695 @ 415V

C15

1200 x 1600 x 800 910 Kg
ESR-600H-3P-T2-S15 600 kVA 911 @ 380V
866 @ 400V
834 @ 415V

C15

1200 x 1600 x 800 1100 Kg
ESR-650H-3P-T2-S15 650 kVA 987 @ 380V
938 @ 400V
904 @ 415V

C36

1500 x 2000 x 1200 1600 Kg
ESR-700H-3P-T2-S15 700 kVA 1063 @ 380V
1010 @ 400V
974 @ 415V

C36

1500 x 2000 x 1200 1610 Kg
ESR-750H-3P-T2-S15 750 kVA 1139 @ 380V
1082 @ 400V
1043 @ 415V

C36

1500 x 2000 x 1200 1620 Kg
ESR-800H-3P-T2-S15 800 kVA 1215 @ 380V
1154 @ 400V
1113 @ 415V

C36

1500 x 2000 x 1200 1630 Kg
ESR-900H-3P-T2-S15 900 kVA 1367 @ 380V
1299 @ 400V
1252 @ 415V

C46

1800 x 2000 x 1300 1900 Kg
ESR-1000H-3P-T2-S15 1000 kVA 1519 @ 380V
1443 @ 400V
1391 @ 415V

C46

1800 x 2000 x 1300 1920 Kg
ESR-1200H-3P-T2-S15 1200 kVA 1823 @ 380V
1732 @ 400V
1669 @ 415V

C46

1800 x 2000 x 1300 2800 Kg
ESR-1250H-3P-T2-S15 1250 kVA 1899 @ 380V
1804 @ 400V
1739 @ 415V

C48

2400 x 2000 x 1000 3300 Kg
ESR-1500H-3P-T2-S15 1500 kVA 2278 @ 380V
2164 @ 400V
2086 @ 415V

C48

2400 x 2000 x 1000 3320 Kg
ESR-1600H-3P-T2-S15 1600 kVA 2430 @ 380V
2309 @ 400V
2225 @ 415V

C48

2400 x 2000 x 1000 3340 Kg
ESR-2000H-3P-T2-S15 2000 kVA 3038 @ 380V
2886 @ 400V
2782 @ 415V

C48

2400 x 2000 x 1000 5500 Kg
ESR-2500H-3P-T3-S15 2500 kVA 3797 @ 380V
3607 @ 400V
3477 @ 415V

C70

3200 x 2200 x 1000 6500 Kg
ESR-3000H-3P-T3-S15 3000 kVA 4557 @ 380V
4329 @ 400V
4172 @ 415V

C70

3200 x 2200 x 1000 7500 Kg
ESR-3125H-3P-T3-S15 3125 kVA 4747 @ 380V
4509 @ 400V
4346 @ 415V

C70

3200 x 2200 x 1000 7520 Kg
ESR-3750H-3P-T3-S15 3750 kVA 5696 @ 380V
5411 @ 400V
5216 @ 415V

C70

3200 x 2200 x 1000 8000 Kg

Addition of Add-On Accessories may affect dimensions and weights stated above.

+ S20 Models - Input Voltage 380/400/415V ±20% >

Input & Output Voltages:
Permissible input voltage windows & output voltage accuracies available for H Series S20 models.


S20 Models / Nominal 380/220V 400/230V 415/240V
Input Voltage Swing % 380V ±20% 400V ±20% 415V ±20%
> L-L Voltage Window 304 to 456V 320 to 480V 332 to 498V
> L-N Voltage Window 176 to 264V 184 to 276V 192 to 288V
Output Voltage Accuracy
> Adjustable
380V ±3% (Default)
±1% to ±5%
400V ±3% (Default)
±1% to ±5%
415V ±3% (Default)
±1% to ±5%
Ratings 250 to 3750 kVA 250 to 3750 kVA 250 to 3750 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings and physical sizes and weights


ESR Model No Rating
kVA
Amps
per Phase
Case
Style
Physical Size
W x H x D (mm)
Weight
Kg
ESR-250H-3P-T1-S20 250 kVA 380 @ 380V
361 @ 400V
348 @ 415V

C14

1050 x 2000 x 700 610 Kg
ESR-300H-3P-T1-S20 300 kVA 456 @ 380V
433 @ 400V
417 @ 415V

C14

1050 x 2000 x 700 730 Kg
ESR-350H-3P-T1-S20 350 kVA 532 @ 380V
505 @ 400V
487 @ 415V

C19

1200 x 2000 x 800 835 Kg
ESR-400H-3P-T1-S20 400 kVA 608 @ 380V
577 @ 400V
556 @ 415V

C19

1200 x 2000 x 800 855 Kg
ESR-450H-3P-T2-S20 450 kVA 684 @ 380V
649 @ 400V
626 @ 415V

C19

1200 x 2000 x 800 950 Kg
ESR-500H-3P-T2-S20 500 kVA 759 @ 380V
721 @ 400V
695 @ 415V

C19

1200 x 2000 x 800 970 Kg
ESR-600H-3P-T2-S20 600 kVA 911 @ 380V
866 @ 400V
834 @ 415V

C36

1500 x 2000 x 1200 1350 Kg
ESR-650H-3P-T2-S20 650 kVA 987 @ 380V
938 @ 400V
904 @ 415V

C36

1500 x 2000 x 1200 1750 Kg
ESR-700H-3P-T2-S20 700 kVA 1063 @ 380V
1010 @ 400V
974 @ 415V

C36

1500 x 2000 x 1200 1760 Kg
ESR-750H-3P-T2-S20 750 kVA 1139 @ 380V
1082 @ 400V
1043 @ 415V

C36

1500 x 2000 x 1200 1770 Kg
ESR-800H-3P-T2-S20 800 kVA 1215 @ 380V
1154 @ 400V
1113 @ 415V

C36

1500 x 2000 x 1200 1780 Kg
ESR-900H-3P-T2-S20 900 kVA 1367 @ 380V
1299 @ 400V
1252 @ 415V

C46

1800 x 2000 x 1300 2350 Kg
ESR-1000H-3P-T2-S20 1000 kVA 1519 @ 380V
1443 @ 400V
1391 @ 415V

C46

1800 x 2000 x 1300 2370 Kg
ESR-1200H-3P-T2-S20 1200 kVA 1823 @ 380V
1732 @ 400V
1669 @ 415V

C46

1800 x 2000 x 1300 3050 Kg
ESR-1250H-3P-T2-S20 1250 kVA 1899 @ 380V
1804 @ 400V
1739 @ 415V

C48

2400 x 2000 x 1000 3450 Kg
ESR-1500H-3P-T2-S20 1500 kVA 2278 @ 380V
2164 @ 400V
2086 @ 415V

C48

2400 x 2000 x 1000 3470 Kg
ESR-1600H-3P-T2-S20 1600 kVA 2430 @ 380V
2309 @ 400V
2225 @ 415V

C48

2400 x 2000 x 1000 3490 Kg
ESR-2000H-3P-T2-S20 2000 kVA 3038 @ 380V
2886 @ 400V
2782 @ 415V

C61

2800 x 2000 x 1000 6000 Kg
ESR-2500H-3P-T3-S20 2500 kVA 3797 @ 380V
3607 @ 400V
3477 @ 415V

C70

3200 x 2200 x 1000 7000 Kg
ESR-3000H-3P-T3-S20 3000 kVA 4557 @ 380V
4329 @ 400V
4172 @ 415V

C70

3200 x 2200 x 1000 8000 Kg
ESR-3125H-3P-T3-S20 3125 kVA 4747 @ 380V
4509 @ 400V
4346 @ 415V

C70

3200 x 2200 x 1000 8020 Kg
ESR-3750H-3P-T3-S20 3750 kVA 5696 @ 380V
5411 @ 400V
5216 @ 415V

C70

3200 x 2200 x 1000 8500 Kg

Addition of Add-On Accessories may affect dimensions and weights stated above.

+ S25 Models - Input Voltage 380/400/415V ±25% >

Input & Output Voltages –
Permissible input voltage windows & output voltage accuracies available for H Series S25 models.


S25 Models / Nominal 380/220V 400/230V 415/240V
Input Voltage Swing % 380V ±25% 400V ±25% 415V ±25%
> L-L Voltage Window 285 to 475V 300 to 500V 311 to 519V
> L-N Voltage Window 165 to 275V 173 to 288V 180 to 300V
Output Voltage Accuracy
> Adjustable
380V ±3% (Default)
±3% to ±5%
400V ±3% (Default)
±3% to ±5%
415V ±3% (Default)
±3% to ±5%
Ratings 250 to 2500 kVA 250 to 2500 kVA 250 to 2500 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings and physical sizes and weights


ESR Model No Rating
kVA
Amps
per Phase
Case
Style
Physical Size
W x H x D (mm)
Weight
Kg
ESR-250H-3P-T1-S25 250 kVA 380 @ 380V
361 @ 400V
348 @ 415V

C19

1200 x 2000 x 800 890 Kg
ESR-300H-3P-T1-S25 300 kVA 456 @ 380V
433 @ 400V
417 @ 415V

C19

1200 x 2000 x 800 1100 Kg
ESR-350H-3P-T1-S25 350 kVA 532 @ 380V
505 @ 400V
487 @ 415V

C30

1500 x 2000 x 1000 1600 Kg
ESR-400H-3P-T1-S25 400 kVA 608 @ 380V
577 @ 400V
556 @ 415V

C30

1500 x 2000 x 1000 1620 Kg
ESR-450H-3P-T2-S25 450 kVA 684 @ 380V
649 @ 400V
626 @ 415V

C30

1500 x 2000 x 1000 1900 Kg
ESR-500H-3P-T2-S25 500 kVA 759 @ 380V
721 @ 400V
695 @ 415V

C30

1500 x 2000 x 1000 1920 Kg
ESR-600H-3P-T2-S25 600 kVA 911 @ 380V
866 @ 400V
834 @ 415V

C36

1500 x 2000 x 1200 2800 Kg
ESR-650H-3P-T2-S25 650 kVA 987 @ 380V
938 @ 400V
904 @ 415V

C46

1800 x 2000 x 1300 3300 Kg
ESR-700H-3P-T2-S25 700 kVA 1063 @ 380V
1010 @ 400V
974 @ 415V

C46

1800 x 2000 x 1300 3310 Kg
ESR-750H-3P-T2-S25 750 kVA 1139 @ 380V
1082 @ 400V
1043 @ 415V

C46

1800 x 2000 x 1300 3320 Kg
ESR-800H-3P-T2-S25 800 kVA 1215 @ 380V
1154 @ 400V
1113 @ 415V

C46

1800 x 2000 x 1300 3330 Kg
ESR-900H-3P-T2-S25 900 kVA 1367 @ 380V
1299 @ 400V
1252 @ 415V

C48

2400 x 2000 x 1000 3600 Kg
ESR-1000H-3P-T2-S25 1000 kVA 1519 @ 380V
1443 @ 400V
1391 @ 415V

C48

2400 x 2000 x 1000 3640 Kg
ESR-1200H-3P-T2-S25 1200 kVA 1823 @ 380V
1732 @ 400V
1669 @ 415V

C70

3200 x 2200 x 1000 4600 Kg
ESR-1250H-3P-T2-S25 1250 kVA 1899 @ 380V
1804 @ 400V
1739 @ 415V

C70

3200 x 2200 x 1000 5800 Kg
ESR-1500H-3P-T2-S25 1500 kVA 2278 @ 380V
2164 @ 400V
2086 @ 415V

C70

3200 x 2200 x 1000 5820 Kg
ESR-1600H-3P-T2-S25 1600 kVA 2430 @ 380V
2309 @ 400V
2225 @ 415V

C70

3200 x 2200 x 1000 5840 Kg
ESR-2000H-3P-T2-S25 2000 kVA 3038 @ 380V
2886 @ 400V
2782 @ 415V

C70

3200 x 2200 x 1000 6500 Kg
ESR-2500H-3P-T3-S25 2500 kVA 3797 @ 380V
3607 @ 400V
3477 @ 415V

C70

3200 x 2200 x 1000 8500 Kg

Addition of Add-On Accessories may affect dimensions and weights stated above.

+ S30 Models - Input Voltage 380/400/415V ±30% >

Input & Output Voltages –
Permissible input voltage windows & output voltage accuracies available for H Series S30 models.


S30 Models / Nominal 380/220V 400/230V 415/240V
Input Voltage Swing % 380V ±30% 400V ±30% 415V ±30%
> L-L Voltage Window 266 to 494V 280 to 520V 291 to 540V
> L-N Voltage Window 154 to 286V 161 to 299V 168 to 312V
Output Voltage Accuracy
> Adjustable
380V ±3% (Default)
±3% to ±5%
400V ±3% (Default)
±3% to ±5%
415V ±3% (Default)
±3% to ±5%
Ratings 250 to 2000 kVA 250 to 2000 kVA 250 to 2000 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings and physical sizes and weights


ESR Model No Rating
kVA
Amps
per Phase
Case
Style
Physical Size
W x H x D (mm)
Weight
Kg
ESR-250H-3P-T1-S30 250 kVA 380 @ 380V
361 @ 400V
348 @ 415V

C19

1200 x 2000 x 800 910 Kg
ESR-300H-3P-T1-S30 300 kVA 456 @ 380V
433 @ 400V
417 @ 415V

C19

1200 x 2000 x 800 1120 Kg
ESR-350H-3P-T1-S30 350 kVA 532 @ 380V
505 @ 400V
487 @ 415V

C30

1500 x 2000 x 1000 1620 Kg
ESR-400H-3P-T1-S30 400 kVA 608 @ 380V
577 @ 400V
556 @ 415V

C30

1500 x 2000 x 1000 1640 Kg
ESR-450H-3P-T2-S30 450 kVA 684 @ 380V
649 @ 400V
626 @ 415V

C30

1500 x 2000 x 1000 1920 Kg
ESR-500H-3P-T2-S30 500 kVA 759 @ 380V
721 @ 400V
695 @ 415V

C30

1500 x 2000 x 1000 1940 Kg
ESR-600H-3P-T2-S30 600 kVA 911 @ 380V
866 @ 400V
834 @ 415V

C36

1500 x 2000 x 1200 2820 Kg
ESR-650H-3P-T2-S30 650 kVA 987 @ 380V
938 @ 400V
904 @ 415V

C46

1800 x 2000 x 1300 3320 Kg
ESR-700H-3P-T2-S30 700 kVA 1063 @ 380V
1010 @ 400V
974 @ 415V

C46

1800 x 2000 x 1300 3330 Kg
ESR-750H-3P-T2-S30 750 kVA 1139 @ 380V
1082 @ 400V
1043 @ 415V

C46

1800 x 2000 x 1300 3340 Kg
ESR-800H-3P-T2-S30 800 kVA 1215 @ 380V
1154 @ 400V
1113 @ 415V

C46

1800 x 2000 x 1300 3350 Kg
ESR-900H-3P-T2-S30 900 kVA 1367 @ 380V
1299 @ 400V
1252 @ 415V

C48

2400 x 2000 x 1000 3620 Kg
ESR-1000H-3P-T2-S30 1000 kVA 1519 @ 380V
1443 @ 400V
1391 @ 415V

C48

2400 x 2000 x 1000 3640 Kg
ESR-1200H-3P-T2-S30 1200 kVA 1823 @ 380V
1732 @ 400V
1669 @ 415V

C70

3200 x 2200 x 1000 4620 Kg
ESR-1250H-3P-T2-S30 1250 kVA 1899 @ 380V
1804 @ 400V
1739 @ 415V

C70

3200 x 2200 x 1000 5800 Kg
ESR-1500H-3P-T2-S30 1500 kVA 2278 @ 380V
2164 @ 400V
2086 @ 415V

C70

3200 x 2200 x 1000 5820 Kg
ESR-1600H-3P-T2-S30 1600 kVA 2430 @ 380V
2309 @ 400V
2225 @ 415V

C70

3200 x 2200 x 1000 5840 Kg
ESR-2000H-3P-T2-S30 2000 kVA 3038 @ 380V
2886 @ 400V
2782 @ 415V

C70

3200 x 2200 x 1000 6520 Kg

Addition of Add-On Accessories may affect dimensions and weights stated above.

+ S35 Models - Input Voltage 380/400/415V ±35% >

Input & Output Voltages –
Permissible input voltage windows & output voltage accuracies available for H Series S35 models.


S35 Models / Nominal 380/220V 400/230V 415/240V
Input Voltage Swing % 380V ±35% 400V ±35% 415V ±35%
> L-L Voltage Window 247 to 513V 260 to 540V 270 to 560V
> L-N Voltage Window 143 to 297V 150 to 311V 156 to 324V
Output Voltage Accuracy
> Adjustable
380V ±3% (Default)
±3% to ±5%
400V ±3% (Default)
±3% to ±5%
415V ±3% (Default)
±3% to ±5%
Ratings 250 to 1200 kVA 250 to 1200 kVA 250 to 1200 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings and physical sizes and weights


ESR Model No Rating
kVA
Amps
per Phase
Case
Style
Physical Size
W x H x D (mm)
Weight
Kg
ESR-250H-3P-T1-S35 250 kVA 380 @ 380V
361 @ 400V
348 @ 415V

C19

1200 x 2000 x 800 960 Kg
ESR-300H-3P-T1-S35 300 kVA 456 @ 380V
433 @ 400V
417 @ 415V

C36

1500 x 2000 x 1200 1340 Kg
ESR-350H-3P-T1-S35 350 kVA 532 @ 380V
505 @ 400V
487 @ 415V

C36

1500 x 2000 x 1200 1740 Kg
ESR-400H-3P-T1-S35 400 kVA 608 @ 380V
577 @ 400V
556 @ 415V

C36

1500 x 2000 x 1200 1760 Kg
ESR-450H-3P-T2-S35 450 kVA 684 @ 380V
649 @ 400V
626 @ 415V

C46

1800 x 2000 x 1300 2340 Kg
ESR-500H-3P-T2-S35 500 kVA 759 @ 380V
721 @ 400V
695 @ 415V

C46

1800 x 2000 x 1300 2360 Kg
ESR-600H-3P-T2-S35 600 kVA 911 @ 380V
866 @ 400V
834 @ 415V

C46

1800 x 2000 x 1300 3420 Kg
ESR-650H-3P-T2-S35 650 kVA 987 @ 380V
938 @ 400V
904 @ 415V

C48

2400 x 2000 x 1000 3430 Kg
ESR-700H-3P-T2-S35 700 kVA 1063 @ 380V
1010 @ 400V
974 @ 415V

C48

2400 x 2000 x 1000 3440 Kg
ESR-750H-3P-T2-S35 750 kVA 1139 @ 380V
1082 @ 400V
1043 @ 415V

C48

2400 x 2000 x 1000 3450 Kg
ESR-800H-3P-T2-S35 800 kVA 1215 @ 380V
1154 @ 400V
1113 @ 415V

C48

2400 x 2000 x 1000 3460 Kg
ESR-900H-3P-T2-S35 900 kVA 1367 @ 380V
1299 @ 400V
1252 @ 415V

C61

2800 x 2200 x 1000 5960 Kg
ESR-1000H-3P-T2-S35 1000 kVA 1519 @ 380V
1443 @ 400V
1391 @ 415V

C61

2800 x 2200 x 1000 5980 Kg
ESR-1200H-3P-T2-S35 1200 kVA 1823 @ 380V
1732 @ 400V
1669 @ 415V

C70

3200 x 2200 x 1000 6980 Kg

Addition of Add-On Accessories may affect dimensions and weights stated above.

+ S40 Models - Input Voltage 380/400/415V ±40% >

Input & Output Voltages –
Permissible input voltage windows & output voltage accuracies available for H Series S40 models.


S40 Models / Nominal 380/220V 400/230V 415/240V
Input Voltage Swing % 380V ±40% 400V ±40% 415V ±40%
> L-L Voltage Window 228 to 532V 240 to 560V 249 to 581V
> L-N Voltage Window 132 to 308V 138 to 322V 144 to 336V
Output Voltage Accuracy
> Adjustable
380V ±3% (Default)
±3% to ±5%
400V ±3% (Default)
±3% to ±5%
415V ±3% (Default)
±3% to ±5%
Ratings 250 to 1200 kVA 250 to 1200 kVA 250 to 1200 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings and physical sizes and weights


ESR Model No Rating
kVA
Amps
per Phase
Case
Style
Physical Size
W x H x D (mm)
Weight
Kg
ESR-250H-3P-T1-S40 250 kVA 380 @ 380V
361 @ 400V
348 @ 415V

C19

1200 x 2000 x 800 970 Kg
ESR-300H-3P-T1-S40 300 kVA 456 @ 380V
433 @ 400V
417 @ 415V

C36

1500 x 2000 x 1200 1350 Kg
ESR-350H-3P-T1-S40 350 kVA 532 @ 380V
505 @ 400V
487 @ 415V

C36

1500 x 2000 x 1200 1760 Kg
ESR-400H-3P-T1-S40 400 kVA 608 @ 380V
577 @ 400V
556 @ 415V

C36

1500 x 2000 x 1200 1780 Kg
ESR-450H-3P-T2-S40 450 kVA 684 @ 380V
649 @ 400V
626 @ 415V

C46

1800 x 2000 x 1300 2350 Kg
ESR-500H-3P-T2-S40 500 kVA 759 @ 380V
721 @ 400V
695 @ 415V

C46

1800 x 2000 x 1300 3420 Kg
ESR-600H-3P-T2-S40 600 kVA 911 @ 380V
866 @ 400V
834 @ 415V

C46

1800 x 2000 x 1300 3430 Kg
ESR-650H-3P-T2-S40 650 kVA 987 @ 380V
938 @ 400V
904 @ 415V

C48

2400 x 2000 x 1000 3440 Kg
ESR-700H-3P-T2-S40 700 kVA 1063 @ 380V
1010 @ 400V
974 @ 415V

C48

2400 x 2000 x 1000 3450 Kg
ESR-750H-3P-T2-S40 750 kVA 1139 @ 380V
1082 @ 400V
1043 @ 415V

C48

2400 x 2000 x 1000 3460 Kg
ESR-800H-3P-T2-S40 800 kVA 1215 @ 380V
1154 @ 400V
1113 @ 415V

C48

2400 x 2000 x 1000 3470 Kg
ESR-900H-3P-T2-S40 900 kVA 1367 @ 380V
1299 @ 400V
1252 @ 415V

C61

2800 x 2200 x 1000 5980 Kg
ESR-1000H-3P-T2-S40 1000 kVA 1519 @ 380V
1443 @ 400V
1391 @ 415V

C61

2800 x 2200 x 1000 6000 Kg
ESR-1200H-3P-T2-S40 1200 kVA 1823 @ 380V
1732 @ 400V
1669 @ 415V

C70

3200 x 2200 x 1000 7000 Kg

Addition of Add-On Accessories may affect dimensions and weights stated above.

+ S45 Models - Input Voltage 380/400/415V ±45% >

Input & Output Voltages –
Permissible input voltage windows & output voltage accuracies available for H Series S45 models.


S45 Models / Nominal 380/220V 400/230V 415/240V
Nominal Swing % 380V ±45% 400V ±45% 415V ±45%
> L-L Voltage Window 209 to 551V 220 to 580V 229 to 601V
> L-N Voltage Window 121 to 319V 127 to 333V 132 to 348V
Output Voltage Accuracy 380V ±5% 400V ±5% 415V ±5%
Ratings 250 to 1200 kVA 250 to 1200 kVA 250 to 1200 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings and physical sizes and weights


ESR Model No Rating
kVA
Amps
per Phase
Case
Style
Physical Size
W x H x D (mm)
Weight
Kg
ESR-250H-3P-T1-S45 250 kVA 380 @ 380V
361 @ 400V
348 @ 415V

C36

1500 x 2000 x 1200 1630 Kg
ESR-300H-3P-T1-S45 300 kVA 456 @ 380V
433 @ 400V
417 @ 415V

C46

1800 x 2000 x 1300 2370 Kg
ESR-350H-3P-T1-S45 350 kVA 532 @ 380V
505 @ 400V
487 @ 415V

C46

1800 x 2000 x 1300 2780 Kg
ESR-400H-3P-T1-S45 400 kVA 608 @ 380V
577 @ 400V
556 @ 415V

C46

1800 x 2000 x 1300 2800 Kg
ESR-450H-3P-T2-S45 450 kVA 684 @ 380V
649 @ 400V
626 @ 415V

C48

2400 x 2000 x 1000 3300 Kg
ESR-500H-3P-T2-S45 500 kVA 759 @ 380V
721 @ 400V
695 @ 415V

C48

2400 x 2000 x 1000 3320 Kg
ESR-600H-3P-T2-S45 600 kVA 911 @ 380V
866 @ 400V
834 @ 415V

C48

2400 x 2000 x 1000 6400 Kg
ESR-650H-3P-T2-S45 650 kVA 987 @ 380V
938 @ 400V
904 @ 415V

C70

3200 x 2200 x 1000 6460 Kg
ESR-700H-3P-T2-S45 700 kVA 1063 @ 380V
1010 @ 400V
974 @ 415V

C70

3200 x 2200 x 1000 6480 Kg
ESR-750H-3P-T2-S45 750 kVA 1139 @ 380V
1082 @ 400V
1043 @ 415V

C70

3200 x 2200 x 1000 6490 Kg
ESR-800H-3P-T2-S45 800 kVA 1215 @ 380V
1154 @ 400V
1113 @ 415V

C70

3200 x 2200 x 1000 6500 Kg
ESR-900H-3P-T2-S45 900 kVA 1367 @ 380V
1299 @ 400V
1252 @ 415V

C70

3200 x 2200 x 1000 7500 Kg
ESR-1000H-3P-T2-S45 1000 kVA 1519 @ 380V
1443 @ 400V
1391 @ 415V

C70

3200 x 2200 x 1000 7520 Kg
ESR-1200H-3P-T2-S45 1200 kVA 1823 @ 380V
1732 @ 400V
1669 @ 415V

C70

3200 x 2200 x 1000 8020 Kg

Addition of Add-On Accessories may affect dimensions and weights stated above.

+ S50 Models - Input Voltage 380/400/415V ±50% >

Input & Output Voltages –
Permissible input voltage windows & output voltage accuracies available for H Series S50 models.


S50 Models / Nominal 380/220V 400/230V 415/240V
Nominal Swing % 380V ±50% 400V ±50% 415V ±50%
> L-L Voltage Window 190 to 570V 200 to 600V 208 to 622V
> L-N Voltage Window 110 to 330V 115 to 345V 120 to 360V
Output Voltage Accuracy 380V ±5% 400V ±5% 415V ±5%
Ratings 250 to 1000 kVA 250 to 1000 kVA 250 to 1000 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings and physical sizes and weights


ESR Model No Rating
kVA
Amps
per Phase
Case
Style
Physical Size
W x H x D (mm)
Weight
Kg
ESR-250H-3P-T1-S50 250 kVA 380 @ 380V
361 @ 400V
348 @ 415V

C46

1800 x 2000 x 1300 1900 Kg
ESR-300H-3P-T1-S50 300 kVA 456 @ 380V
433 @ 400V
417 @ 415V

C46

1800 x 2000 x 1300 2780 Kg
ESR-350H-3P-T1-S50 350 kVA 532 @ 380V
505 @ 400V
487 @ 415V

C46

1800 x 2000 x 1300 3300 Kg
ESR-400H-3P-T1-S50 400 kVA 608 @ 380V
577 @ 400V
556 @ 415V

C46

1800 x 2000 x 1300 3320 Kg
ESR-450H-3P-T2-S50 450 kVA 684 @ 380V
649 @ 400V
626 @ 415V

C48

2400 x 2000 x 1000 5480 Kg
ESR-500H-3P-T2-S50 500 kVA 759 @ 380V
721 @ 400V
695 @ 415V

C48

2400 x 2000 x 1000 5500 Kg
ESR-600H-3P-T2-S50 600 kVA 911 @ 380V
866 @ 400V
834 @ 415V

C70

3200 x 2200 x 1000 7480 Kg
ESR-650H-3P-T2-S50 650 kVA 987 @ 380V
938 @ 400V
904 @ 415V

C70

3200 x 2200 x 1000 7490 Kg
ESR-700H-3P-T2-S50 700 kVA 1063 @ 380V
1010 @ 400V
974 @ 415V

C70

3200 x 2200 x 1000 7500 Kg
ESR-750H-3P-T2-S50 750 kVA 1139 @ 380V
1082 @ 400V
1043 @ 415V

C70

3200 x 2200 x 1000 7510 Kg
ESR-800H-3P-T2-S50 800 kVA 1215 @ 380V
1154 @ 400V
1113 @ 415V

C70

3200 x 2200 x 1000 7530 Kg
ESR-900H-3P-T2-S50 900 kVA 1367 @ 380V
1299 @ 400V
1252 @ 415V

C70

3200 x 2200 x 1000 7980 Kg
ESR-1000H-3P-T2-S50 1000 kVA 1519 @ 380V
1443 @ 400V
1391 @ 415V

C70

3200 x 2200 x 1000 8000 Kg

Addition of Add-On Accessories may affect dimensions and weights stated above.

+ Digital Display Panel & RS-485 Remote Communications >

LCD Digital Display Panel

ESR-Display-Panel-HComprehensive LCD Digital Monitoring and Control Panel delivering intuitive control and monitoring of all the key system parameters.

Real Time Display of

  • Voltage: Individual and Average Output Phase Voltages
  • Current: Individual and Average Phase Currents
  • Operational Status: On AVR and On Bypass
  • Alarm Conditions: Overload, Over-Voltage, Under-Voltage, Fuse Failure and Phase Failure

Modifiable System Parameter Settings of

  • Output Voltage
  • Output Voltage Accuracy
  • Correction Time
  • Voltage Regulation Method

 

  • Over-Voltage
  • Under-Voltage
  • Over Current Value

Optional Additional Digital Metering of

  • Input Voltage: Digital Power Meters showing Input Voltage (Phase to Phase & Phase to Neutral)
  • Frequency: Digital Frequency Meter
  • Power Factor: Digital Power Factor Meter

RS-485 Remote Communication:

All ESR Voltage Stabilisers offer as standard RS-485 communication which will enable the following information to be available for remote monitoring –

Measurements –

  • Input Voltage: Phase to Phase and Phase to Neutral
  • Output Voltage: Phase to Phase and Phase to Neutral
  • Current: Phase Currents

Status Indication – 

  • Over Voltage
  • Under Voltage

 

  • Current Overload
  • Fuse Blown

+ Standard Enclosure Types >

Offered as standard in IP20 / NEMA 1 Style floor standing air-cooled cubicles, ESR Stabilisers are built utilising a rigid framework construction, offering front door access and removable side panels for ease of installation and servicing.

Supplied with bottom cable entry (top entry on C70 style enclosures or to specific order), all cubicles are offered  complete with an epoxy powder heavy duty Pebble Grey (RAL 7032) orange peel paint finish.

Where deemed appropriate ESR stabiliser can also, on individual request, be supplied in robust IP54 / NEMA 3 Style enclosures – ideal for outdoor applications or more demand indoor environments.

Standard C14 to C46 Style IP20 / NEMA 1 Enclosures
Bottom cable entry at the front

ESR-C14-C46


Enclosure
Style
Physical Size
W x H x D (mm)
Packed Size
W x H x D (cm)
Case Weight
(Kg)
C14 1050 x 2000 x 700 110 x 215 x 75 +160 Kg
C15 1200 x 1600 x 800 125 x 175 x 85 +165 Kg
C19 1200 x 2000 x 800 125 x 215 x 85 +200 Kg
C30 1500 x 2000 x 1000 155 x 215 x 105 +270 Kg
C36 1500 x 2000 x 1200 155 x 215 x 125 +310 Kg
C46 1800 x 2000 x 1300 185 x 215 x 135 +380 Kg

Addition of Add-On Accessories may affect dimensions and weights stated above.

Standard C48 to C70 Style IP20 / NEMA 1 Enclosures
Bottom cable entry at the front (C70 – Top Cable Entry on L/R Sides)

ESR-C48-C70


Enclosure
Style
Physical Size
W x H x D (mm)
Packed Size
W x H x D (cm)
Case Weight
(Kg)
C48 2400 x 2000 x 1000 245 x 215 x 105 +400 Kg
C61 2800 x 2200 x 1000 285 x 235 x 105 +490 Kg
C70 3200 x 2200 x 1000 325 x 235 x 105 +560 Kg

Addition of Add-On Accessories may affect dimensions and weights stated above.

Copyright © VSI (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE

+ Permissible Input Voltage Window Options & Output Voltage Accuracy >

SWING-ESR-250-3750-sm2

Input Voltage Windows:

In situations where there is a reasonably good mains supply, a Stabiliser offering an input variation swing of ±15% (S15 Models) will usually be more than acceptable, but in more remote locations, or countries where the national supply infrastructure is less developed, variations of ±20% (S20) or greater ±25% (S25) to ±50% (S50) may be needed to be accommodated by the Stabiliser.

TIP – The wider the permissible input voltage window you wish the Stabiliser to be able to accommodate , the more expensive the Stabiliser. So, when selecting the most appropriate and cost efficient model for your application, it pays to know the state of the utility mains supply on site and the designed input voltage tolerances of the load equipment you wish to protect.

Output Voltage Accuracy:

In general, when suppliers of today’s modern electrical and electronic equipment design their products they do so knowing that most electrical utilities around the world cannot provide, or promise, better than a ±5% output voltage accuracy of nominal and as such they design their equipment so it is able to operate efficiently within this range.

ESR Stabilisers are specifically designed to meet the requirements of today’s modern loads, with the output voltage accuracy set (as default) to deliver optimal energy efficiency and design life expectancy at ±3% , however they are easily site-adjustable to deliver a more or less precise output voltage accuracy – as considered most appropriate for a client’s particular site needs.

+ General Technical Specifications >

This Specification covers the general technical performance of the H-X468 Series (440 to 480V) Three Phase 4 Wire (with Neutral) ESR Series Voltage Stabilisers / Power Line Conditioners in ratings from 250 to 3750 kVA.

NB:  3 Wire (without Neutral) HD-X468 Series models are also available – please checkout the Brochure Downloads TAB on the right to download the relevant HD-X468 Series brochure.


SPECIFICATION
GENERAL
Design Topology: Static -Digital Buck-Boost SCR Design
Electrical Configuration: Three Phase, 4 Wire, (3 Phase + Neutral + G/E)
Power Ratings: 250 kVA, 300 kVA, 350 kVA, 400 kVA, 450 kVA,
500 kVA, 600 kVA, 650 kVA, 700 kVA, 750 kVA,
800 kVA, 900 kVA, 1000 kVA, 1200 kVA, 1250 kVA,
1500 kVA, 1600 kVA, 2000 kVA & 2500 kVA
- smaller ratings to order
Power Factor: The Power Factor has no effect on performance providing
the stabiliser is being used within its rated capacity
Frequency: 35 to 63Hz
INPUT
Voltage: 440/256V - 460/265V - 480/277V (Customer to Specify)
Voltage Swing Options
Available:
±15% (S15 Models - up to 2500 kVA)
±20% (S20 Models - up to 2500 kVA)
±25% (S25 Models - up to 2000 kVA)
±30% (S30 Models - up to 1600 kVA)
±35% (S35 Models - up to 1000 kVA)
±40% (S40 Models - up to 1000 kVA)
±45% (S45 Models - up to 1000 kVA)
±50% (S50 Models - up to 800 kVA)
(Customer to Specify)
Frequency: 35 to 63Hz
OUTPUT
Voltage: 440/256V - 460/265V - 480/277V (Customer to Specify)
Voltage Regulation: S15 to S20 Models ±3% (Default) - Adjustable ±1 to ±5%
S25 to S40 Models ±3% (Default) - Adjustable ±3 to ±5%
S45 to S50 Models ±5%
Frequency: 35 to 63Hz
Response Time: <0.04 seconds
Correction Time: 40 msec per Step
PROTECTION FEATURES
Surge Suppression: TVSS - Protects loads against high energy
Spikes and Transient Voltages
SPD Surge Arrestors: Class 2 Type Surge Protection Device - protects the load
and stabiliser against high energy voltage spikes of
operational or atmospheric origin (eg. Lightning induced spikes)
Independent Phase
Control:
Maintains each phases voltage stable irrespective of load
unbalance, even up to 100% load unbalance
Start-Up Protection: Protection of the load equipment from damaging start up
voltage surges
Automatic Bypass: Automatic transfer to bypass in the event of an
overload or system problem
Overload Capacity: 5 x max. current rating for 1 second
1.5 x max. current rating for 1 minute
Short Circuit & Overload
Switch / Breaker Protection
and Manual Bypass
facility:
250 to 400 kVA Rated Models
Type 1 (T1) style switch arrangement
consists of an input switch and bypass switch, with output
isolation, with mechanical interlocking to prevent
inadvertent mis-operation

450 to 2000 kVA Rated Models
Type 2 (T2) style switch arrangement consists of a
motorised input air switch and output / bypass changeover
switch, with full electronic interlocking to prevent inadvertent
mis-operation

2500 kVA + Rated Models
Type 3 (T3) style switch arrangement similar to the
Type 2 arrangement, but utilising separate motorised
air output and bypass switches, with full electronic interlocking
to prevent inadvertent mis-operation

For further details see Breaker / Switch Configurations and
Control Panels Tab below

ENVIRONMENTAL
Operating Temperature
Range:
Temperature range 0 to 45 °C
Derate by 2% for each additional °C Up to max 60 °C
Maximum Altitude: Maximum altitude 4000m
Derate by 2.5% for each additional 500m
Relative Humidity: Suitable for indoor tropical use 90% RH (non-condensing)
Efficiency: =>98%
THD - Harmonic Distortion: None introduced
Audible Noise: < 45 dB (at 1 Metre)
PHYSICAL
Construction: Enclosures to IP20 (NEMA 1 Style) - BS EN 60529
Colour: RAL 7032 (Pebble Grey - Epoxy Powder Coating)
Dimensions & Weights: See S15 to S50 Tabs below
CONFORMANCE
EMC Conformance: Complies with BS EN 55022 and the relevant parts of
the BS EN 61000 series of standards
CE Certification:: CE Marked - being fully compliant with European Union
Directives 2014/30/EU (The EMC Directive) and
2014/35/EU (The Low Voltage Directive)
WARRANTY
Standard Warranty: 2 Year / 24 Months from date of supply
Extended Warranty: Option - Extendable Warranty up to 60 Months / 5 Years
ADD-ON OPTIONS
Input Isolating
Transformer:
Through the inclusion of a shielded isolation transformer,
provides enhanced spike & electrical noise (common &
normal interference) suppression and neutral
ground bonding. Delivers what is commonly
referred to as a ‘CLEAN’ supply
Outdoor IP54
Ingress Protection:

(-IP54)
Stabiliser presented in an endurable IP54 (BS / EN 60529)
/ NEMA 3 free standing steel cubicles suitable for
external use, or more challenging internal environments
AquaStop:
(-AS)
PCB protective coating offering protection against
damp and moisture ingress
Alternative Switch
Arrangements:

(-T2 or T3)
Alternative Input, Output and Bypass Switching arrangements
- T2 (250 to 400 kVA)
- T3 (250 to 2000 kVA)
See Short Circuit & Overload Switch / Breaker Protection
and Manual Bypass facility Section above
Additional Metering:
(-ADM)
Additional Digital Metering for
- Input Volts
- Frequency
- Power Factor
4 Pole Switches / Breakers:
(-FP)
As standard ESR Stabilisers utilise 3 Pole Switches / Breakers.
As an option 4 Pole alternatives can be supplied.
eSpec Upgrade:
(-eSP)
While we endeavour to keep production costs to a minimum
by sourcing top specification components from
around the globe we realise that some clients have a
requirement for their own designated protection devices

Accordingly we are able to offer our eSpec Pack Upgrade
package which offers the client the short circuit and
overcurrent protection components from their preferred
leading European or American manufacturers

+ S15 Models - Input Voltage 440/460/480V ±15% >

Input & Output Voltages:
Permissible input voltage windows & output voltage accuracies available for H-X468 Series S15 models.


S15 Models / Nominal 440/256V 460/265V 480/277V
Input Voltage Swing % 440V ±15% 460V ±15% 480V ±15%
> L-L Voltage Window 374 to 506V 391 to 529V 408 to 552V
> L-N Voltage Window 216 to 292V 225 to 305V 235 to 319V
Output Voltage
Accuracy

(Adjustable)
Default -
440V ±3%
(±1% to ±5%)
Default -
460V ±3%
(±1% to ±5%)
Default -
480V ±3%
(±1% to ±5%)
Ratings 250 to 2500 kVA 250 to 2500 kVA 250 to 2500 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings –


ESR Model No Power
Rating
Amps
per Phase
@440V
Amps
per Phase
@460V
Amps
per Phase
@480V
ESR-250H-3P-T1-S15-X468 250 kVA 328 314 301
ESR-300H-3P-T1-S15-X468 300 kVA 394 376 361
ESR-350H-3P-T1-S15-X468 350 kVA 459 439 421
ESR-400H-3P-T1-S15-X468 400 kVA 525 502 481
ESR-450H-3P-T2-S15-X468 450 kVA 590 565 541
ESR-500H-3P-T2-S15-X468 500 kVA 656 627 601
ESR-600H-3P-T2-S15-X468 600 kVA 787 753 721
ESR-650H-3P-T2-S15-X468 650 kVA 853 816 782
ESR-700H-3P-T2-S15-X468 700 kVA 918 878 842
ESR-750H-3P-T2-S15-X468 750 kVA 984 941 902
ESR-800H-3P-T2-S15-X468 800 kVA 1049 1004 962
ESR-900H-3P-T2-S15-X468 900 kVA 1181 1129 1082
ESR-1000H-3P-T2-S15-X468 1000 kVA 1312 1255 1202
ESR-1200H-3P-T2-S15-X468 1200 kVA 1574 1506 1443
ESR-1250H-3P-T2-S15-X468 1250 kVA 1640 1568 1503
ESR-1500H-3P-T2-S15-X468 1500 kVA 1968 1882 1804
ESR-1600H-3P-T2-S15-X468 1600 kVA 2099 2008 1924
ESR-2000H-3P-T2-S15-X468 2000 kVA 2624 2510 2405
ESR-2500H-3P-T3-S15-X468 2500 kVA 3279 3137 3006

Physical sizes and weights available on request.

+ S20 Models - Input Voltage 440/460/480V ±20% >

Input & Output Voltages:
Permissible input voltage windows & output voltage accuracies available for H-X468 Series S20 models.


S20 Models / Nominal 440/256V 460/265V 480/277V
Input Voltage Swing % 440V ±20% 460V ±20% 480V ±20%
> L-L Voltage Window 352 to 528V 368 to 552V 384 to 576V
> L-N Voltage Window 203 to 305V 212 to 318V 222 to 332V
Output Voltage
Accuracy

(Adjustable)
Default -
440V ±3%
(±1% to ±5%)
Default -
460V ±3%
(±1% to ±5%)
Default -
480V ±3%
(±1% to ±5%)
Ratings 250 to 2500 kVA 250 to 2500 kVA 250 to 2500 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings –


ESR Model No Power
Rating
Amps
per Phase
@440V
Amps
per Phase
@460V
Amps
per Phase
@480V
ESR-250H-3P-T1-S20-X468 250 kVA 328 314 301
ESR-300H-3P-T1-S20-X468 300 kVA 394 376 361
ESR-350H-3P-T1-S20-X468 350 kVA 459 439 421
ESR-400H-3P-T1-S20-X468 400 kVA 525 502 481
ESR-450H-3P-T2-S20-X468 450 kVA 590 565 541
ESR-500H-3P-T2-S20-X468 500 kVA 656 627 601
ESR-600H-3P-T2-S20-X468 600 kVA 787 753 721
ESR-650H-3P-T2-S20-X468 650 kVA 853 816 782
ESR-700H-3P-T2-S20-X468 700 kVA 918 878 842
ESR-750H-3P-T2-S20-X468 750 kVA 984 941 902
ESR-800H-3P-T2-S20-X468 800 kVA 1049 1004 962
ESR-900H-3P-T2-S20-X468 900 kVA 1181 1129 1082
ESR-1000H-3P-T2-S20-X468 1000 kVA 1312 1255 1202
ESR-1200H-3P-T2-S20-X468 1200 kVA 1574 1506 1443
ESR-1250H-3P-T2-S20-X468 1250 kVA 1640 1568 1503
ESR-1500H-3P-T2-S20-X468 1500 kVA 1968 1882 1804
ESR-1600H-3P-T2-S20-X468 1600 kVA 2099 2008 1924
ESR-2000H-3P-T2-S20-X468 2000 kVA 2624 2510 2405
ESR-2500H-3P-T3-S20-X468 2500 kVA 3279 3137 3006

Physical sizes and weights available on request.

+ S25 Models - Input Voltage 440/460/480V ±25% >

Input & Output Voltages:
Permissible input voltage windows & output voltage accuracies available for H-X468 Series S25 models.


S25 Models / Nominal 440/256V 460/265V 480/277V
Input Voltage Swing % 440V ±25% 460V ±25% 480V ±25%
> L-L Voltage Window 330 to 550V 345 to 575V 360 to 600V
> L-N Voltage Window 191 to 318V 199 to 331V 208 to 346V
Output Voltage
Accuracy

(Adjustable)
Default -
440V ±3%
(±3% to ±5%)
Default -
460V ±3%
(±3% to ±5%)
Default -
480V ±3%
(±3% to ±5%)
Ratings 250 to 2000 kVA 250 to 2000 kVA 250 to 2000 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings –


ESR Model No Power
Rating
Amps
per Phase
@440V
Amps
per Phase
@460V
Amps
per Phase
@480V
ESR-250H-3P-T1-S25-X468 250 kVA 328 314 301
ESR-300H-3P-T1-S25-X468 300 kVA 394 376 361
ESR-350H-3P-T1-S25-X468 350 kVA 459 439 421
ESR-400H-3P-T1-S25-X468 400 kVA 525 502 481
ESR-450H-3P-T2-S25-X468 450 kVA 590 565 541
ESR-500H-3P-T2-S25-X468 500 kVA 656 627 601
ESR-600H-3P-T2-S25-X468 600 kVA 787 753 721
ESR-650H-3P-T2-S25-X468 650 kVA 853 816 782
ESR-700H-3P-T2-S25-X468 700 kVA 918 878 842
ESR-750H-3P-T2-S25-X468 750 kVA 984 941 902
ESR-800H-3P-T2-S25-X468 800 kVA 1049 1004 962
ESR-900H-3P-T2-S25-X468 900 kVA 1181 1129 1082
ESR-1000H-3P-T2-S25-X468 1000 kVA 1312 1255 1202
ESR-1200H-3P-T2-S25-X468 1200 kVA 1574 1506 1443
ESR-1250H-3P-T2-S25-X468 1250 kVA 1640 1568 1503
ESR-1500H-3P-T2-S25-X468 1500 kVA 1968 1882 1804
ESR-1600H-3P-T2-S25-X468 1600 kVA 2099 2008 1924
ESR-2000H-3P-T2-S25-X468 2000 kVA 2624 2510 2405

Physical sizes and weights available on request.

+ S30 Models - Input Voltage 440/460/480V ±30% >

Input & Output Voltages:
Permissible input voltage windows & output voltage accuracies available for H-X468 Series S30 models.


S30 Models / Nominal 440/256V 460/265V 480/288V
Input Voltage Swing % 440V ±30% 460V ±30% 480V ±30%
> L-L Voltage Window 308 to 572V 322 to 598V 336 to 624V
> L-N Voltage Window 178 to 330V 186 to 345V 194 to 360V
Output Voltage
Accuracy

(Adjustable)
Default -
440V ±3%
(±3% to ±5%)
Default -
460V ±3%
(±3% to ±5%)
Default -
480V ±3%
(±3% to ±5%)
Ratings 250 to 1600 kVA 250 to 1600 kVA 250 to 1600 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings –


ESR Model No Power
Rating
Amps
per Phase
@440V
Amps
per Phase
@460V
Amps
per Phase
@480V
ESR-250H-3P-T1-S30-X468 250 kVA 328 314 301
ESR-300H-3P-T1-S30-X468 300 kVA 394 376 361
ESR-350H-3P-T1-S30-X468 350 kVA 459 439 421
ESR-400H-3P-T1-S30-X468 400 kVA 525 502 481
ESR-450H-3P-T2-S30-X468 450 kVA 590 565 541
ESR-500H-3P-T2-S30-X468 500 kVA 656 627 601
ESR-600H-3P-T2-S30-X468 600 kVA 787 753 721
ESR-650H-3P-T2-S30-X468 650 kVA 853 816 782
ESR-700H-3P-T2-S30-X468 700 kVA 918 878 842
ESR-750H-3P-T2-S30-X468 750 kVA 984 941 902
ESR-800H-3P-T2-S30-X468 800 kVA 1049 1004 962
ESR-900H-3P-T2-S30-X468 900 kVA 1181 1129 1082
ESR-1000H-3P-T2-S30-X468 1000 kVA 1312 1255 1202
ESR-1200H-3P-T2-S30-X468 1200 kVA 1574 1506 1443
ESR-1250H-3P-T2-S30-X468 1250 kVA 1640 1568 1503
ESR-1500H-3P-T2-S30-X468 1500 kVA 1968 1882 1804
ESR-1600H-3P-T2-S30-X468 1600 kVA 2099 2008 1924

Physical sizes and weights available on request.

+ S35 Models - Input Voltage 440/460/480V ±35% >

Input & Output Voltages:
Permissible input voltage windows & output voltage accuracies available for H-X468 Series S35 models.


S35 Models / Nominal 440/256V 460/265V 480/277V
Input Voltage Swing % 440V ±35% 460V ±35% 480V ±35%
> L-L Voltage Window 286 to 594V 299 to 621V 312 to 648V
> L-N Voltage Window 165 to 343V 172 to 358V 180 to 374V
Output Voltage
Accuracy

(Adjustable)
Default -
440V ±3%
(±3% to ±5%)
Default -
460V ±3%
(±3% to ±5%)
Default -
480V ±3%
(±3% to ±5%)
Ratings 250 to 1000 kVA 250 to 1000 kVA 250 to 1000 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings –


ESR Model No Power
Rating
Amps
per Phase
@440V
Amps
per Phase
@460V
Amps
per Phase
@480V
ESR-250H-3P-T1-S35-X468 250 kVA 328 314 301
ESR-300H-3P-T1-S35-X468 300 kVA 394 376 361
ESR-350H-3P-T1-S35-X468 350 kVA 459 439 421
ESR-400H-3P-T1-S35-X468 400 kVA 525 502 481
ESR-450H-3P-T2-S35-X468 450 kVA 590 565 541
ESR-500H-3P-T2-S35-X468 500 kVA 656 627 601
ESR-600H-3P-T2-S35-X468 600 kVA 787 753 721
ESR-650H-3P-T2-S35-X468 650 kVA 853 816 782
ESR-700H-3P-T2-S35-X468 700 kVA 918 878 842
ESR-750H-3P-T2-S35-X468 750 kVA 984 941 902
ESR-800H-3P-T2-S35-X468 800 kVA 1049 1004 962
ESR-900H-3P-T2-S35-X468 900 kVA 1181 1129 1082
ESR-1000H-3P-T2-S35-X468 1000 kVA 1312 1255 1202

Physical sizes and weights available on request.

+ S40 Models - Input Voltage 440/460/480V ±40% >

Input & Output Voltages:
Permissible input voltage windows & output voltage accuracies available for H-X468 Series S40 models.


S40 Models / Nominal 440/256V 460/265V 480/277V
Input Voltage Swing % 440V ±40% 460V ±40% 480V ±40%
> L-L Voltage Window 264 to 616V 276 to 644V 288 to 672V
> L-N Voltage Window 152 to 356V 159 to 371V 166 to 388V
Output Voltage
Accuracy

(Adjustable)
Default -
440V ±3%
(±3% to ±5%)
Default -
460V ±3%
(±3% to ±5%)
Default -
480V ±3%
(±3% to ±5%)
Ratings 250 to 1000 kVA 250 to 1000 kVA 250 to 1000 kVA

Smaller rated models (6 to 200 kVA) also available – Learn more

Model Selection:
Available power ratings –


ESR Model No Power
Rating
Amps
per Phase
@440V
Amps
per Phase
@460V
Amps
per Phase
@480V
ESR-250H-3P-T1-S40-X468 250 kVA 328 314 301
ESR-300H-3P-T1-S40-X468 300 kVA 394 376 361
ESR-350H-3P-T1-S40-X468 350 kVA 459 439 421
ESR-400H-3P-T1-S40-X468 400 kVA 525 502 481
ESR-450H-3P-T2-S40-X468 450 kVA 590 565 541
ESR-500H-3P-T2-S40-X468 500 kVA 656 627 601
ESR-600H-3P-T2-S40-X468 600 kVA 787 753 721
ESR-650H-3P-T2-S40-X468 650 kVA 853 816 782
ESR-700H-3P-T2-S40-X468 700 kVA 918 878 842
ESR-750H-3P-T2-S40-X468 750 kVA 984 941 902
ESR-800H-3P-T2-S40-X468 800 kVA 1049 1004 962
ESR-900H-3P-T2-S40-X468 900 kVA 1181 1129 1082
ESR-1000H-3P-T2-S40-X468 1000 kVA 1312 1255 1202

Physical sizes and weights available on request.

+ S45 Models - Input Voltage 440/460/480V ±45% >

Input & Output Voltages:
Permissible input voltage windows & output voltage accuracies available for H-X468 Series S45 models.


S45 Models / Nominal 440/256V 460/265V 480/277V
Input Voltage Swing % 440V ±45% 460V ±45% 480V ±45%
> L-L Voltage Window 242 to 638V 253 to 667V 264 to 696V
> L-N Voltage Window 141 to 371V 146 to 384V 153 to 401V
Output Voltage Accuracy 440V ±5% 460V ±5% 480V ±5%
Ratings 250 to 1000 kVA 250 to 1000 kVA 250 to 1000 kVA

Model Selection:
Available power ratings –


ESR Model No Power
Rating
Amps
per Phase
@440V
Amps
per Phase
@460V
Amps
per Phase
@480V
ESR-250H-3P-T1-S45-X468 250 kVA 328 314 301
ESR-300H-3P-T1-S45-X468 300 kVA 394 376 362
ESR-350H-3P-T1-S45-X468 350 kVA 459 439 421
ESR-400H-3P-T1-S45-X468 400 kVA 525 502 481
ESR-450H-3P-T2-S45-X468 450 kVA 590 565 541
ESR-500H-3P-T2-S45-X468 500 kVA 656 627 602
ESR-600H-3P-T2-S45-X468 600 kVA 787 753 721
ESR-650H-3P-T2-S45-X468 650 kVA 853 816 782
ESR-700H-3P-T2-S45-X468 700 kVA 918 878 842
ESR-750H-3P-T2-S45-X468 750 kVA 984 941 902
ESR-800H-3P-T2-S45-X468 800 kVA 1049 1004 962
ESR-900H-3P-T2-S45-X468 900 kVA 1181 1129 1082
ESR-1000H-3P-T2-S45-X468 1000 kVA 1312 1255 1202

Physical sizes and weights available on request.

+ S50 Models - Input Voltage 440/460/480V ±50% >

Input & Output Voltages:
Permissible input voltage windows & output voltage accuracies available for H-X468 Series S50 models.


S50 Models / Nominal 440/256V 460/265V 480/277V
Input Voltage Swing % 440V ±50% 460V ±50% 480V ±50%
> L-L Voltage Window 220 to 660V 230 to 690V 240 to 720V
> L-N Voltage Window 126 to 384V 133 to 397V 139 to 415V
Output Voltage Accuracy 440V ±5% 460V ±5% 480V ±5%
Ratings 250 to 800 kVA 250 to 800 kVA 250 to 800 kVA

Model Selection:
Available power ratings –


ESR Model No Power
Rating
Amps
per Phase
@440V
Amps
per Phase
@460V
Amps
per Phase
@480V
ESR-250H-3P-T1-S50-X468 250 kVA 328 314 301
ESR-300H-3P-T1-S50-X468 300 kVA 394 376 361
ESR-350H-3P-T1-S50-X468 350 kVA 459 439 421
ESR-400H-3P-T1-S50-X468 400 kVA 525 502 481
ESR-450H-3P-T2-S50-X468 450 kVA 590 565 541
ESR-500H-3P-T2-S50-X468 500 kVA 656 627 601
ESR-600H-3P-T2-S50-X468 600 kVA 787 753 721
ESR-650H-3P-T2-S50-X468 650 kVA 853 816 782
ESR-700H-3P-T2-S50-X468 700 kVA 918 878 842
ESR-750H-3P-T2-S50-X468 750 kVA 984 941 902
ESR-800H-3P-T2-S50-X468 800 kVA 1049 1004 962

Physical sizes and weights available on request.

+ Digital Display Panel & RS-485 Remote Communications >

LCD Digital Display Panel

ESR-Display-Panel-HComprehensive LCD Digital Monitoring and Control Panel delivering intuitive control and monitoring of all the key system parameters.

Real Time Display of

  • Voltage: Individual and Average Output Phase Voltages
  • Current: Individual and Average Phase Currents
  • Operational Status: On AVR and On Bypass
  • Alarm Conditions: Overload, Over-Voltage, Under-Voltage, Fuse Failure and Phase Failure

Modifiable System Parameter Settings of

  • Output Voltage
  • Output Voltage Accuracy
  • Correction Time
  • Voltage Regulation Method

 

  • Over-Voltage
  • Under-Voltage
  • Over Current Value

Optional Additional Digital Metering of

  • Input Voltage: Digital Power Meters showing Input Voltage (Phase to Phase & Phase to Neutral)
  • Frequency: Digital Frequency Meter
  • Power Factor: Digital Power Factor Meter

RS-485 Remote Communication:

All ESR Voltage Stabilisers offer as standard RS-485 communication which will enable the following information to be available for remote monitoring –

Measurements –

  • Input Voltage: Phase to Phase and Phase to Neutral
  • Output Voltage: Phase to Phase and Phase to Neutral
  • Current: Phase Currents

Status Indication – 

  • Over Voltage
  • Under Voltage

 

  • Current Overload
  • Fuse Blown

+ Standard Enclosure Types >

Offered as standard in IP20 / NEMA 1 Style floor standing air-cooled cubicles, ESR Stabilisers are built utilising a rigid framework construction, offering front door access and removable side panels for ease of installation and servicing.

Supplied with bottom cable entry (top entry on C70 style enclosures or to specific order), all cubicles are offered  complete with an epoxy powder heavy duty Pebble Grey (RAL 7032) orange peel paint finish.

Where deemed appropriate ESR stabiliser can also, on individual request, be supplied in robust IP54 / NEMA 3 Style enclosures – ideal for outdoor applications or more demand indoor environments.

C14 to C46 Style IP20 / NEMA 1 Enclosures
Bottom cable entry at the front

ESR-C14-C46


Enclosure
Style
Physical Size
W x H x D (mm)
Packed Size
W x H x D (cm)
Case Weight
(Kg)
C14 1050 x 2000 x 700 110 x 215 x 75 +160 Kg
C15 1200 x 1600 x 800 125 x 175 x 85 +165 Kg
C19 1200 x 2000 x 800 125 x 215 x 85 +200 Kg
C30 1500 x 2000 x 1000 155 x 215 x 105 +270 Kg
C36 1500 x 2000 x 1200 155 x 215 x 125 +310 Kg
C46 1800 x 2000 x 1300 185 x 215 x 135 +380 Kg

Addition of Add-On Accessories may affect dimensions and weights stated above.

C48 to C70 Style IP20 / NEMA 1 Enclosures
Bottom cable entry (C70 Top Cable Entry on L/R Sides)

ESR-C48-C70


Enclosure
Style
Physical Size
W x H x D (mm)
Packed Size
W x H x D (cm)
Case Weight
(Kg)
C48 2400 x 2000 x 1000 245 x 215 x 105 +400 Kg
C61 2800 x 2200 x 1000 285 x 235 x 105 +490 Kg
C70 3200 x 2200 x 1000 325 x 235 x 105 +560 Kg

Addition of Add-On Accessories may affect dimensions and weights stated above.

Copyright © VSI (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE

+ Brochures / Data Sheets

To download / view the relevant PDF Data Sheets simply chick on the PDF icons below.


4 Wire Solutions

(With Neutral)

H Series
380/220V - 415/240V


H-X468 Series
440/256V - 480/277V



3 Wire Solutions

(NO Neutral)

HD Series
380 - 415V
HD-X468 Series
440- 480V

+ Operator and User Manuals


Range

Breaker Configuration

Operator Manual

H & HD Series

T1 - 250 to 400 kVA

T2 - 450 to 2000 kVA

T3 - 2500 kVA and Up

+ CE Certification

ESR Series Three Phase AC Voltage Stabilisers comply with the relevant European Union (EU) health, safety and environmental protection directives and regulations and are duly CE marked.


Document Type Relevant EU Directive Certificate
VSI Declaration EMC Directive - 2014/30/EU - in force from April 2016
Low Voltage Directive - 2014/35/EU - in force from April 2016
Independent 3rd Party
Verification Certificates
EMC Directive - 2014/30/EU - in force from April 2016
Low Voltage Directive - 2014/35/EU - in force from April 2016

Copyright © VSI (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE

ESR-250-3750-WP2


4 Wire Solutions

(With Neutral)

H Series
380/220V - 415/240V


H-X468 Series
440/256V - 480/277V



3 Wire Solutions

(NO Neutral)

HD Series
380 - 415V
HD-X468 Series
440- 480V